atNorth data centers
CPP Investments (c. 51% controlling stake) with Equinix (c. 34%) and Partners Group (c. 10%) · private (CPP Investments controlling; Equinix minority; Partners Group retained stake)
Data centers
8
Countries
4
Reported MW
0 MW
Pipeline MW
0 MW
Building area
34,688 m²
Est. energy / yr
392.3 GWh
Est. CO₂ / yr
23 kt
Median PUE
1.21
ecoSustainability — operator-wide
Hover a value for the quote from the reportboltEnergy
Total energy
256.2 GWh
Operator-wide 2025 · company-wide (all data centers + fuels)
Data-center electricity
252,286 MWh (renewable electricity purchased)
Operator-wide 2025 · all sites
Renewable share
99.1 % of total energy
Operator-wide 2025 · company-wide; remaining 0.9% fossil fuel (2,390 MWh)
Renewable procurement
Renewable electricity backed by Guarantees of Origin; long-term PPAs named as future strategy; Nordic hydro/geothermal grids
Operator-wide 2025 · group
Average PUE
1.21 PUE
Operator-wide 2025 · portfolio annual average (1.28 in 2024; target <=1.20)
cloudEmissions
Scope 1
178 tCO₂e
Operator-wide 2025 · group (generators 38%, vehicles 36%, refrigerants 26%)
Scope 2 location-based
2.4 ktCO₂e
Operator-wide 2025 · group
Scope 2 market-based
98 tCO₂e
Operator-wide 2025 · group
Scope 3
59.5 ktCO₂e
Operator-wide 2025 · group (capital goods 51%, purchased goods 44%)
Carbon intensity
654 tCO2e/USD million revenue (market-based); 0.23 tCO2e/MWh tCO2e/USDm; tCO2e/MWh
Operator-wide 2025 · group, total emissions
Refrigerant emissions
46 tCO2e (derived: 26% of 178 t scope 1 stated as fugitive)
Operator-wide 2025 · group
water_dropWater
Water consumption
9,600 m³
Operator-wide 2025 · all sites (10,200 m3 in 2024); WUE not reported due to metering
recyclingWaste
Waste generated
47.7 kt
Operator-wide 2025 · group incl. construction 47,500 t; operations 178 t (102,598 t in 2024)
Waste diverted from landfill
86 % recovered
Operator-wide 2025 · total (operations 90%)
flagTargets & commitments
Net-zero target
2050
Operator-wide 2025 · group; zero operational (Scope 1&2) emissions by 2030; -50% Scope 3 vs 2025 by 2030
SBTi
committed/in process: SBTi target-setting initiated, validation expected 2026
Operator-wide 2025 · group
ISO 14001
ISO 14001 certified (also ISO 9001, ISO 27001, ISO 45001)
Operator-wide 2025 · company
Heat-reuse projects
Active at 2 of 7 operational sites: FIN02 Helsinki -> Kesko supermarket; SWE01 Stockholm -> Stockholm Exergi district heating. Planned: FIN01 (2026), DEN01 Copenhagen/Vestforbraending & DEN02 (2028). Target: all operational sites by 2028
Operator-wide 2025 · group
Backup fuel / HVO
78% of generator fuel used is HVO
Operator-wide 2025 · group
business_centerBusiness
Data centers
8 operational data centers
Operator-wide 2026 · plus four mega sites and one Stockholm metro site under development
Pipeline capacity
1,000 MW secured power
Operator-wide 2026 · group (secured power incl. development)
Countries
5 countries
Operator-wide 2026 · Iceland, Denmark, Sweden, Finland, Norway (Norway site Haugaland under development, power 2028)
Employees
229 employees
Operator-wide 2025 · group (163 in 2024)
Headquarters
Iceland
Operator-wide 2026 · group
campaignNotable
Notable facts
Acquired by CPP Investments and Equinix from Partners Group (announced 27 Feb 2026) at US$4bn enterprise value with US$4.2bn financing; Norway Haugaland mega site 120 MW growing to 350 MW; Solleftea (SWE04) 300 MW mega site; tree-planting with Crusoe (65,000+ trees)
Operator-wide 2026 · group
mapFootprint
publicData centers by country
dnsData centers
8 · largest first| Data center | Status | Capacity | Building | PUE | Energy (est) | Networks |
|---|---|---|---|---|---|---|
| atNorth ICE03 Akureyri, IS | Operational | 12 MW | 5,350 m² | 1.2 | 94.1 GWh | 0 |
| atNorth FIN02 Espoo, FI | Operational | — | 12,865 m² | 1.2 | 132 GWh | 0 |
| atNorth DEN01 Skovlunde, DK | Operational | — | 9,285 m² | 1.2 | 53.3 GWh | 0 |
| atNorth FIN01 Helsinki, FI | Operational | — | 2,527 m² | 1.3 | 18.1 GWh | 2 |
| atNorth ICE01 Hafnafjörður, IS | Operational | — | 2,256 m² | 1.2 | 37.6 GWh | 0 |
| M03 Reykjanesbær, IS | Operational | — | 1,491 m² | 1.21 | 8.6 GWh | — |
| atNorth FIN03 Espoo, FI | Operational | — | 914 m² | 1.21 | 10.6 GWh | 0 |
| atNorth SWE01 Stockholm, SE | Operational | — | — | 1.21 | 38 GWh | 3 |
atNorth ICE03
12 MW
atNorth · Akureyri, Iceland
atNorth FIN02
≈ 21 MW
atNorth · Espoo, Finland
atNorth DEN01
≈ 8.4 MW
atNorth · Skovlunde, Denmark
atNorth FIN01
≈ 2.6 MW
atNorth · Helsinki, Finland
atNorth ICE01
≈ 6 MW
atNorth · Hafnafjörður, Iceland
M03
≈ 1.4 MW
atNorth · Reykjanesbær, Iceland
atNorth FIN03
≈ 1.7 MW
atNorth · Espoo, Finland
atNorth · Stockholm, Sweden